MODULUX Ceiling System
Easy to install – Modulux panels weigh less
than one third the weight of drywall panels, making manipulation
and installation much easier.
Clean – Repairs are easy to make without causing
a mess. Users can replace single sections or full sheets without filling
the room with messy residue.
Economical – Convenient staple attachment method
and fast concealment of joints with styrene moldings enables manufacturers
to increase throughput. No waiting time needed, no separate operations.
Quality – A distinctive pattern provides high
light reflectance. Time-tested coating ensures minimum maintenance
and provides resistance
to discoloration and fading.
Surface Burning Characteristics – Class II
tested and labeled with a flame spread rating of 70 in accordance with
CAN/ULC-S102
test procedure
Physical Properties
Thickness: ½"
Normal Width: 4'
Lengths: 70½" – 84" – 96" – 117" – 141"
Weight: 646 lbs per 1000 square feet
approx. 31lbs per 4' x 12' panel
Property
|
|
Test Method |
Unit |
Test Results |
| Density |
|
ASTM C209 |
lb/113 |
15.5 |
| Moisture Content |
|
ASTM D1037 |
% |
8.4 |
| Modulus of Rupture |
|
ASTM C209 |
psi |
250 |
| Tensile Strength |
Parallel to surface
|
ASTM C209 |
psi |
175 |
| |
Perpendicular to surface |
ASTM C209 |
psi |
285 |
| Water Absorption |
|
ASTM C209 |
% in 2 hr. |
9 |
| Noise Reduction Coefficient (NRC) |
|
ASTM C423 |
|
0.30 (Textura) |
| Flame Spread Classification |
|
CANULC-S102 |
|
70 |
| Fuel Contribution |
|
CANULC-S102 |
|
53 |
| Smoke Developed |
|
CANULC-S102 |
|
49 |
| Linear Expansion (50% RH to 90% RH) |
|
ASTM D1037 |
% |
0.4 |
MODULUX provides manufacturers with a beautiful surface pattern and a tough abrasion-resistant
surface.
MODULUX incorporates color coordinated molding sets to conceal staples and give
the ceiling an attractive, uniform look.
MODULUX panels are formed from wood fibers and special moisture-resistant agents
into a rich, deep-embossed pattern. A durable abrasion-resistant coating system
helps the embossed surface resist denting and damage during assembly.
MODULUX Surface Burning Characteristics – Class II tested and labled
with a flame spread rating of 70 in accordance with CAN/ULC-S102 test procedure.
Directions for Use
Notes to Manufacturer
- Insulation should be batt-type installed between trusses, or blanket-type
installed atop trusses.
- Where applicable, a polyethylene vapor retarder should be installed across
truss faces before installation of ceiling board.
- MODULUX panels are not recommended where exposure to moisture is extreme.
Storage and handling of materials
- Store MODULUX panels in a cool, dry place. Keep covered to prevent soiling.
- Unwrap ceiling panel units at least 72 hours before application so that
panels will stabilize to prevailing temperature and humidity.
- Handle and apply MODULUX panels by grasping ends, not edges of panels.
Bill of materials
- MODULUX Ceiling Panels Textura pattern, ½" x 4' nominal x (specify
length)
- Staples GSW16: 1" crown x 1½" leg, galvanized and coated
- Female styrene moulding. 1 per panel of equal length
- Male styrene moulding, 2 per panel (12/24" stud configuration) or
3 per panel (16" stud configuration) of equal length as panel.
Assembly Instructions
Color match for MODULUX ceiling
Technical Drawings
 |
 |
MODULUX CEILING SYSTEM
16" JOIST VERSION
Click on image for larger view
|
MODULUX CEILING SYSTEM
12/24" JOIST VERSION
Click on image for larger view |
| Adobe Acrobat is required to view the larger files (click
for Free Download). |
|